AJAX EN54 Fire Hub Black
SKU: 125733
Trade price hidden
Prices are reserved for approved trade accounts. Register and we'll unlock the full catalogue pricing.
CapacityDevicesup to 200Supports Ajax devices from the EN54 product line, wireless intrusion devices, and resettable buttons for manual fire alarm activation in
Description & specs
CapacityDevicesup to 200Supports Ajax devices from the EN54 product line, wireless intrusion devices, and resettable buttons for manual fire alarm activation in any combination, except for the following:up to 10 intrusion sirens;up to 50 keypads with a built-in buzzer;up to up to 5 EN54 Fire ReX Jeweller range extenders.More about devicesFire zonesup to 40Alerts about fire in separate zones. Every zone may include multiple rooms.Ajax NVRsup to 36Learn moreAjax camerasup to 224 via Ajax NVRs and up to 492 standaloneLearn moreThird-party IP camerasup to 10 when using RTSP via SDKup to 224 when using ONVIF via Ajax NVRsLearn moreUsersup to 200Any number of admin users within the CIE limit.PRO accounts for installers.PRO accounts for installation and monitoring companies.Access management for users.Automation scenariosup to 64By alarm.By schedule.By arming/disarming.By temperature, humidity, CO2 concentration.By pressing Button.By touching LightSwitch.Learn moreRoomsup to 80Event logup to 5,000 eventsFire alarm system events. Can be viewed on the CIE display. Events are saved on the non-volatile onboard flash memory.up to 500 eventsFire alarm, intrusion, and other system events. Can be viewed in the events feed in Ajax apps.CommunicationJeweller communication technologyProprietary wireless communication technology to transmit commands, alarms, and events.Key features:Two-way communication.Advanced sabotage protection.Block encryption featuring a dynamic key.Instant notifications.Remote control and configuration in Ajax apps.Learn moreFrequency bands866.0–866.5 MHz868.0–868.6 MHz868.7–869.2 MHz905.0–926.5 MHz915.85–926.5 MHz921.0–922.0 MHzDepends on the sales region.Maximum effective radiated power (ERP)up to 20 mWAutomatic power control to reduce power consumption and radio interference.Radio signal modulationGFSKRadio communication rangeup to 1,800 mBetween the CIE and connected devices (in an open space). Maximum range depends on the connected device.Learn moreEncrypted communicationAll stored and transmitted data are protected by block encryption featuring a dynamic key.Frequency hoppingTo prevent radio interference and jamming.Learn moreWings communication technologyProprietary wireless communication technology to transmit photo verifications and update firmware.Key features: Two-way communication.Advanced sabotage protection.Block encryption featuring a dynamic key.Data packages reload in case of transmission errors.Photo delivery check.Frequency bands866.0–866.5 MHz868.0–868.6 MHz868.7–869.2 MHz905.0–926.5 MHz915.85–926.5 MHz921.0–922.0 MHzDepends on the sales region.Radio communication range up to 1,800 mBetween the CIE and connected devices (in an open space). Maximum range depends on the connected device.Learn moreEncrypted communicationAll stored and transmitted data is protected by block encryption featuring a dynamic key.Frequency hoppingTo prevent radio interference and jamming.Learn moreCommunication channelsEthernet1 8P8C socket Up to 100 Mbps. Cellular2 micro-SIM slotsCellular frequencies2GGSM900/DCS1800 (B3/B8)4G (LTE)FDD B1/B3/B5/B7/B8/B20 Wi-Fi 802.11 b/g/n moduleup to 72 Mbps.Automatic switching between communication channelsInstant switching between Ethernet, Wi-Fi, and SIM.Instant switching between 4G (LTE), 3G, and 2G networks of one SIM.Switching between SIMs takes up to 4 minutes.Communication channels prioritization1. Ethernet2. Wi-Fi3. Cellular connectionCommunication channels work in parallel to increase the system’s reliability. Most of the data is transmitted via Ethernet.NotificationsSupported notification typesPush notificationsSMSCallsLearn moreEvent typesAlarmsVideo alertsFaults (for fire alarm devices)Malfunctions (for other Ajax devices)Security state changeSystem eventsNon-security alertsAutomation devicesSmart lock eventsDoorbell ringingThe notification types are configured individually for each user. MonitoringSupported protocolsSIA (DC-09)SurGard (Contact ID)Learn moreEvent typesSystem alarms and eventsPanic button coordinatesPhoto verificationLearn moreFire alarm system managementIndication of fire alarms and faultsdisplayLED indicatorssoundLEDs on the front panel of the CIE and the built-in buzzer notify users of fire alarms in zones, faults, and system states. In case of fire, the CIE also activates visual alarm devices and fire alarm sounders. The CIE display also shows system states and detailed alarm information.Fire alarm controlstart evacuationresetmute buzzersilence / resound soundersoverride delays (coming soon)indication testUsers with appropriate rights can manage the fire alarm system via these options.Fire alarm system settingsUsers with appropriate rights can configure all fire alarm system settings via the CIE.Event logStores a detailed log of fire alarms and system events. Capacity: up to 5,000 events.Photo verificationPhoto verification typesPhoto by alarmPhoto by scenarioPhoto on demandPhoto by schedulePhoto by arming/disarmingMore about photo by scenarioMore about photo on demandMore about photo by scheduleMore about photo by arming/disarmingPhoto delivery timeup to 9 sBy default.Learn morePhoto resolutionup to 960 × 720 pixelsDepends on the detector.Number of photos in a seriesfrom 1 to 5 picturesAdditional featuresUser authorization To manage the fire alarm system via the CIE touch screen, the user must log in by entering a code or presenting a personal access device.ControlcodesTag key fobs (coming soon)Pass cards (coming soon)Contactless access (coming soon)DESFire® EV1, EV2ISO14443-А (13.56 MHz)Access codesup to 200 codes One code per each user. Defines user access level to security and fire alarm system management.Duress codesup to 200 personal codes One code per each user. Built-in buzzervolume at least 60 dB at a distance of 1 mSound alerts of fire alarms.volume at least 50 dB at a distance of 1 mSound alerts of faults.LED indicationredFor fire alarms.yellowFor device faults, tests, and disablements. greenFor power supply status. Special tool (key)The special tool is used to unlock the housing and replace the internal battery or dismantle the device from the SmartBracket mounting panel. The battery is not included in the CIE complete set.Learn more DisplayDiagonal10.1″Matrix typeIPSResolution1024 × 600 pxSensorcapacitiveBacklight settingsManually adjustable in the CIE on-screen settings.Interface languageConfigurable via the CIE touch screen or in the CIE settings in Ajax apps.OutputsOutput 1Relay output for alerting the monitoring company in case of a system fault. Contact state is normally closed (NC) by default.Output 2Relay output for alerting the monitoring company in case of a fire alarm. Contact state is normally open (NO) by default.Operating modebistableExternal power supply10–30 V⎓The relay does not supply power to connected devices.Energy consumption up to 60 WIn standby mode.Maximum resistive loadup to 2 A at 30 V⎓Maximum inductive/capacitive loadup to 2 A at 30 V⎓Installation recommendationsThe device is designed for indoor use only.Use GlandBox if power and signal cables are not routed inside the wall.The device operating voltage is 110–240 V~.Sabotage protectionTamper buttonNotifications about the fault on attempts to detach the device from the surface or remove the mounting panel.Learn moreProtection against spoofingdevice authenticationConnection loss detectionafter 36 sDetection time depends on Jeweller settings.Power supplyExternal 110–240 V, 50/60 HzUp to 0.48 A of mains power consumption.Internal7.4 V⎓, 5 Ah/10 AhOn Rechargeable Li-ion battery not included in the complete set: EN54 Internal Battery (24h) or EN54 Internal Battery (72h).Learn moreAutonomous operationOn internal batteryup to 24 hoursOn EN54 Internal Battery (24h) not included in the complete set. Battery life is based on display activation only when tapped, using W-Fi, Ethernet, and cellular (LTE) communication channels.up to 72 hoursOn EN54 Internal Battery (72h) not included in the complete set. Battery life is based on display activation only when tapped, using W-Fi, Ethernet, and cellular (LTE) communication channels.Learn moreEnclosureDimensions263 × 223 × 54 mmWeight1,526 gOperating temperature rangefrom -10 °C to +40 °COperating humidityup to 75% non-condensingProtection classIP20Flammability ratingUL 94 V-0